List of all parameters included in the Windows environment Monitoring service

 

Parameter Description OK WARNING CRITICAL
CPU Load Monitors the percentage of CPU capacity being utilized by system processes. CPU utilization < 85% CPU utilization >= 85% CPU utilization >= 95%
Memory Usage Monitors the total system RAM usage (used vs. free memory). Free/available memory is >= 10% Free/available memory is < 10% Free/available memory is < 5%
NSClient++ Version Checks the available free disk space on the logical drive partitions. NSClient++ installed/running and version is approved NSClient++ running but version is outdated/mismatch NSClient++ not responding / not running
Uptime Monitors the duration the system has been running to detect unexpected reboots or service interruptions. Uptime is normal (no unexpected recent reboot) Recent reboot detected (within warning window) Very recent reboot or unable to read uptime
Portscan Checks whether specific (expected) ports are open or closed on the server. All required ports are in the expected state Non-critical port mismatch detected Critical port mismatch (required closed/open) detected
Network Traffic Embedded Monitors data throughput and error rates on the integrated (on-board) network interface. Network traffic within expected range Traffic unusually high/low or error rate increasing Traffic at critical level or interface down/errors severe
Network Traffic SLOT * Port * - *G Monitors data throughput and performance for network cards installed in specific hardware slots. Network traffic within expected range Traffic unusually high/low or error rate increasing Traffic at critical level or interface down/errors severe
PING Checks if the server is reachable on the network, measures packet loss, and Round Trip Time (RTA). Host reachable with acceptable latency and no/low loss Packet loss and/or latency above warning threshold Host unreachable or loss/latency at critical level
Drive Space Checks the available free disk space on all mounted logical drives (e.g., C:, D:). Free space is >= 20% Free space is < 20% Free space is < 10%
RAID NVMe Checks the health and redundancy status of the NVMe storage array. RAID/volume healthy RAID/volume degraded but operational RAID/volume failed or data at risk
RAID PERC HDD - RAID-HDD Monitors the health and status of the hardware RAID array consisting of mechanical hard drives. RAID healthy/optimal RAID degraded but operational RAID failed or data at risk
RAID PERC SSD - RAID-SSD-OS Monitors the health and status of the hardware RAID array consisting of SSDs hosting the OS. RAID healthy/optimal RAID degraded but operational RAID failed or data at risk
SMART HDD disk slot Checks the Self-Monitoring, Analysis, and Reporting Technology (SMART) status for HDDs in specific slots. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure
SMART NVMe disk Checks the SMART health attributes and remaining life percentage for NVMe storage devices. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure
SMART SSD disk slot Checks the SMART status and wear-leveling indicators for SSDs in specific slots. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure
 

Test

test

 

CPU Load Monitors the percentage of CPU capacity being utilized by system processes. CPU utilization < 85% CPU utilization >= 85% CPU utilization >= 95%
Memory Usage Monitors the total system RAM usage (used vs. free memory). Free/available memory is >= 10% Free/available memory is < 10% Free/available memory is < 5%
NSClient++ Version Checks the available free disk space on the logical drive partitions. NSClient++ installed/running and version is approved NSClient++ running but version is outdated/mismatch NSClient++ not responding / not running
Uptime Monitors the duration the system has been running to detect unexpected reboots or service interruptions. Uptime is normal (no unexpected recent reboot) Recent reboot detected (within warning window) Very recent reboot or unable to read uptime
Portscan Checks whether specific (expected) ports are open or closed on the server. All required ports are in the expected state Non-critical port mismatch detected Critical port mismatch (required closed/open) detected
Network Traffic Embedded Monitors data throughput and error rates on the integrated (on-board) network interface. Network traffic within expected range Traffic unusually high/low or error rate increasing Traffic at critical level or interface down/errors severe
Network Traffic SLOT * Port * - *G Monitors data throughput and performance for network cards installed in specific hardware slots. Network traffic within expected range Traffic unusually high/low or error rate increasing Traffic at critical level or interface down/errors severe
PING Checks if the server is reachable on the network, measures packet loss, and Round Trip Time (RTA). Host reachable with acceptable latency and no/low loss Packet loss and/or latency above warning threshold Host unreachable or loss/latency at critical level
Drive Space Checks the available free disk space on all mounted logical drives (e.g., C:, D:). Free space is >= 20% Free space is < 20% Free space is < 10%
RAID NVMe Checks the health and redundancy status of the NVMe storage array. RAID/volume healthy RAID/volume degraded but operational RAID/volume failed or data at risk
RAID PERC HDD - RAID-HDD Monitors the health and status of the hardware RAID array consisting of mechanical hard drives. RAID healthy/optimal RAID degraded but operational RAID failed or data at risk
RAID PERC SSD - RAID-SSD-OS Monitors the health and status of the hardware RAID array consisting of SSDs hosting the OS. RAID healthy/optimal RAID degraded but operational RAID failed or data at risk
SMART HDD disk slot Checks the Self-Monitoring, Analysis, and Reporting Technology (SMART) status for HDDs in specific slots. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure
SMART NVMe disk Checks the SMART health attributes and remaining life percentage for NVMe storage devices. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure
SMART SSD disk slot Checks the SMART status and wear-leveling indicators for SSDs in specific slots. SMART status OK SMART indicates degrading attributes SMART reports failure or imminent failure